    The Command Water and Air System controls a Single-Speed Water Pump and a Multi-Speed Blower. The user interface is four-buttons with an LED light over each button.

    Requires the following components
    CONTROL BOX #: CIMC-263-01-03-01
    CONTROL BOX #: CIDU-252-01-06-13
    KEYPAD #: CIDU-252-01-06-13
    KEYPAD CABLE #: CCBL-168

    Optional Components
    TRIM RING #: CRING-xx

    Upon power up of the system without user intervention, the display will enter the standby mode of the configuration previously set. In standby mode:
    ♦ The user can operate the pump. The LED above the “Jets” icon will light dimly to indicate that the blower is operable.
    ♦ The user can operate the blower. The LED above the “Blower” icon will light dimly to indicate that the blower is operable.

    TIMERS
    Pressing and releasing the “Jets” icon button will turn on the pump and start a 20-minute run timer. Pressing and releasing the “Jets” icon button a second time during the 20-minute run time will turn off the pump and cancel the timer. If the 20-minute run time expires, the pump and blower will turn off. If the pump is shut down by the user before the 20-minute time expires, the blower will continue operating until the 20-minute time expires or is turned off by the user.
    Pressing and releasing the “Blower” icon button will turn the blower on and start a 20-minute run timer. Pressing and releasing the “Blower” icon button a second time during the 20-minute run time will turn off the blower and cancel the timer. If the 20-minute run time expires, the blower and pump will turn off. If the blower is shut down by the user before the 20-minute time expires, the pump will continue operating until the 20-minute time expires or is turned off by the user.

    PUMP CONTROL
    When the “Jets” icon button is active (indicated by a dimly lit LED above the “Jets” icon) pressing and releasing the button will turn on the pump and start a 20-minute run timer. The operating pump will be indicated by a full bright LED above the “Jets” icon. Pressing and releasing the button a second time during the 20 minute run time will turn off the pump and cancel the timer.

    BLOWER CONTROL
    When the “Blower” button is active (indicated by a dimly lit LED above the “Light” icon) pressing and releasing the button will turn the blower on in high speed and start a 20-minute run timer. The operating blower will be indicated by a full-bright LED above the “Blower” icon. Pressing and releasing the button a second time during the 20 minute run time will turn off the blower and cancel the timer. While the blower is functioning, pressing and holding the “Blower” icon button for two seconds will activate the “+” and “-“ buttons, indicated by the LEDs over the
    “+” and “-“ buttons illuminating full-bright. Pressing either “+” or “-“ button will increase or decrease the speed of the blower. Pressing the “-“ button for two seconds at the lowest speed will cause the blower to enter the wave mode. When in the wave mode, the blower will slowly cycle between high and low speeds. Pressing either “+” or “-“ button will exit the wave mode at the current blower speed setting. The “+” and “-“ buttons will remain active (lit) for ten seconds without input, and then extinguish.

    DRY CYCLE
    20 minutes after the blower and pump have been idle; the blower will turn on for 1 minute to dry the air lines and air jets. The blower will start at low speed for about 6 seconds, ramp to high speed over about 5 seconds and remain at high speed for the duration of the cycle. During the dry cycle, the LED over the “Blower” icon will blink. Pressing the “Blower” icon button during the dry cycle will stop the dry cycle.