Command Plus Water System
Requires the following components
CONTROL BOX #: CIMC-263-01-03-01
KEYPAD #: CIDU-254-01-06-13
KEYPAD CABLE #: CCBL-168
WATER TEMP SENSOR #: CITW-209-01-01-01
MULTI-COLORED LIGHT #: CICL-239-01-01-01
LIGHT CABLE #: CCBL-170
Optional Components
TRIM RING #: CRING-xx
EXTENDED LIGHT CABLE #: CCBL-176
WATER SENSE CABLE #: CCBL-128
“Y” LIGHT CABLE #: CCBL-233
The Command Plus Water System controls a Single-Speed Water Pump and Colored LED light(s). The system includes capacitive water level sensing and temperature display. The user interface is a two-button display with a digital display.
System Functions
Upon power up of the system without user intervention, the display will enter the standby mode of the configuration previously set. In standby mode:
♦ The display will be blank until water is sensed.
♦ If the user attempts to operate the pump, “No H2O” will be displayed
♦ The user can operate the color LED light(s).
TIMERS
When the “Jets” icon button is active (indicated by the water temperature displayed) pressing and releasing the button will turn on the pump and start a 20-minute run timer. Pressing and releasing the “Jets” icon button a second time during the 20-minute run time will turn off the pump and cancel the timer. If the 20-minute run time expires, the pump and light(s) will turn off. If the pump is shut down by the user before the 20-minute timer expires, the light(s) will continue operating.
WATER / TEMPERATURE SENSING
When water is sensed by the circuit for 5 continuous seconds the display will show the water temperature and the “Jets” icon button will become active. The button will remain active as long as water is sensed. If water is not sensed for more than 2 seconds continuously, the “Jets” icon button will become inactive, the display will indicate “No H2O”, and the pump will turn off.
PUMP CONTROL
When the “Jets” icon button is active (indicated by the water temperature displayed) pressing and releasing the button will turn on the pump and start a 20-minute run timer. Pressing and releasing the button a second time during the 20-minute run time will turn off the pump and cancel the timer.
LIGHT CONTROL
Pressing the “Light” icon button will start the colored LED light(s) in color changing mode. The display will indicate “C00” for color-changing mode. Pressing and holding the “Light” icon button for two seconds will move the light through the seven individual colors (indicated by “C01 through C07” on the display) and then back to color changing mode. Releasing the button will hold the light at the color displayed. Pressing the “Light” icon button will turn the lights off. The light will come back on in the color it displayed when it was turned off.