Command Plus Air / Water System

    Various

    Command Plus Air/Water System

    Command Plus Air/Water System

    Requires the following components
    CONTROL BOX #: CIMC-263-01-03-01
    CONTROL BOX #: CIAU-214-01-03-01
    KEYPAD #: CIDU-215-01-04-01
    KEYPAD BASE #: CRING-59-BASE
    KEYPAD TRIM RING #: CRING-60-xx
    KEYPAD CABLE #: CCBL-168
    WATER TEMP SENSOR #: CITW-209-01-01-01
    MULTI-COLORED LIGHT #: CICL-239-01-01-01
    LIGHT CABLE #: CCBL-170

    Optional Components
    TRIM RING #: CRING-xx
    EXTENDED LIGHT CABLE #: CCBL-176
    WATER SENSE CABLE #: CCBL-128
    “Y” LIGHT CABLE #: CCBL-233

    The Command Plus Water & Air System controls a Single-Speed Pump, a Multi-Speed Blower, and Colored LED light(s). The system includes capacitive water level sensing and temperature display. The user interface is an eight-button display with a digital display.

    Upon power up of the system without user intervention, the display will enter the standby mode of the configuration previously set. In standby mode:
    ♦ The display will be blank until water is sensed.
    ♦ If the user attempts to operate the timer, pump, or blower, “No H2O” will be displayed
    ♦ The user can operate the color LED light(s). (Button 5 displayed dimly)

    TIMER (B1)
    When the display is in standby mode and water feedback is being detected, Button 1 (clock icon) will illuminate and flash, indicating the button is available to set the system timer. Pressing and holding button 1 will cause the display scroll through the available system times; 10 minutes, 15 minutes, 20 minutes, 25 minutes, and 30 minutes, releasing the button on the desired time will start the system timer and the countdown from the selected time will commence. The remaining time will be indicated on the display. Once the time is set, Buttons 2, 3, and
    5 will illuminate and flash, and Buttons 7 and 8 will illuminate. When the selected time expires all operating systems will turn off. Pressing Button 1 while systems are operating will allow the remaining time to be increased.

    TEMPERATURE DISPLAY UNITS
    The display can be set to show in either Fahrenheit or Celsius scale. Holding Button 1 after the display reads “30” during the timer programming for another 8 seconds will move the display into the temperature scale selection mode where the display will alternate between the 2 scales. Once the desired scale is displayed, release the button and the display will be programmed to always show the temperature in those units. After the scale has been selected, the display will perform a reset.

    WATER / TEMPERATURE SENSING
    When water is sensed by the circuit for 5 continuous seconds the display will show the water temperature and Buttons 1 will become active (indicated by flashing). The button will remain active as long as water is sensed. If water is not sensed for more than 2 seconds continuously while systems are operating, Buttons1, 2, 3, 7, and 8 will become inactive (indicated by dark), the display will indicate “No H2O”, and all operating systems will turn off.

    PUMP CONTROL (B2)
    Once the timer has been set, the pump can be run in single-speed mode indicated by Button 2 (jet icon) illuminated and flashing. Pressing and releasing Button 2 will turn the pump on and off and show “ON” or “OFF” on the display.

    BLOWER CONTROL (B3)
    Once the timer has been set, the blower can be run in multi-speed mode indicated by Button 3 (bubbles icon) illuminated and flashing. Pressing and releasing Button 3 will turn the blower on and off and show “SP6” or “OFF” on the display. To vary the speed, pressing and holding Button 3 will start the blower at high speed and after 2 seconds begin to decrease down to the lowest speed. The display will indicate the speeds down to the lowest speed (“SP6” – “SP1”). Continuing to hold Button 3 for 2 seconds while in lowest speed (“SP1”) will activate the wave mode for the blower, and the display will indicate “WA”. When in the wave mode, the blower will slowly cycle
    between high and low speeds. Pressing Button 3 while in the wave mode will exit the blower from wave mode at the current speed the blower is running. The blower will always turn on in high speed (“SP6”).

    DRY CYCLE
    20 minutes after the blower has been idle and no water has been detected, the blower will activate for 1 minute to dry the air lines and air jets. The blower will start at low speed for about 6 seconds, ramp to high speed over about 5 seconds and remain at high speed for the duration of the cycle. During the dry cycle the display will indicate “DRY”, and Button 3 (bubbles icon) will flash. Pressing Button 3 during the dry cycle will stop the dry cycle.

    BUTTON 4 (B4)
    Button 4 is for future options and is dark.

    LIGHT CONTROL (B5)
    Pressing Button 4 (light icon) will start the colored LED light(s) in color changing mode. The display will indicate “C00” for color-changing mode. Pressing and holding the “Light” button for two seconds will move the light through the seven individual colors (indicated by “C01 through C07” on the display) and then back to color changing mode. Releasing the button will hold the light at the color displayed. Pressing the “Light” button will turn the lights off. The light will come back on in the color it displayed when it was turned off.

    BUTTON 6 (B6)
    Button 6 is for future options and is dark.