Air Activated Controller

    CAST-201-01-01-XXX

    Air Activated Controller

    NuWhirl's Air-Activated Controller is a NEMA plug-in pre-programmed, stand-alone control with functions which include blower timing, speed control and dry cycle functions. All operated by an Air Button interface for ease of use.

    Air Activated Controller

    ELECTRICAL SPECIFICATIONS:
    120VAC 60HZ RATED 11.5 AMPS, NEMA/NEMA Plug-in UL1795 Recognized / Meets CSA No. 218

    OPERATING SEQUENCE for CAST-201-01-01-04A
    First Press ON / HIGH SPEED
    Second Press MEDIUM SPEED
    Third Press LOW SPEED
    Fourth Press MASSAGE MODE - Oscillates between High and Low Speeds
    Fifth Press OFF

    TIMING SEQUENCE for CAST-201-01-01-04A: Timer 20 Minutes
    Dry Cycle 1 Minute - 20 Minutes After System Shut-Off

    PRODUCT DIMENSIONS (appx.)
    6.80” h x 2.15” d x 3.45” w (170mm x 55 mmm x 88mm)

    The printed circuit board is conformal coated for protection against corrosion and includes an automatic shut-o after 20
    minutes. Additional configurations are available (CAST-201-01-01-XXX).

    The Dry Cycle function automatically starts 20 minutes after operation ceases and runs for one minute to reduce moisture
    in the air lines. This function works even if the blower is turned off before the automatic shut-off.

    The Air-Activated Controller plugs into any standard 120VAC outlet. The blower plugs into the Controller.

    NuWhirl’s air button and air tubing also plug into the controller and are used to activate the system. All components are modular and easily removable for service or repair.